B-Series Breakout Interlocking Armor (ILA) Plenum Rated Cables

Applications:

  • Ideal for industrial and other installations requiring a metallic armor
  • Interlocking armor may eliminate the need for conduit, reducing installation costs

Features:

  • Inner cable is a fully functional B-Series Breakout Plenum Rated Cable
  • Cable materials are indoor/outdoor – UL-listed OFCP and UV, water and fungus resistant
  • UL listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces
  • Aluminum interlocking armor with plenum fluoropolymer (K) overjacket
  • Greater flexibility than standard corrugated steel-armored (CST) cables
  • Interlocking armor can be easily removed, leaving an intact inner cable
  • 2.0mm subunits are standard
  • Wide operating temperature of -40°C to +85°C for (K jacket) cables
  Plenum (2.0mm)
Operating Temperature -40°C to +85°C
Storage Temperature -40°C to +85°C
Installation Temperature (cable temp.) 0°C to +60°C (cable temp.)
Flame Retardancy UL listed OFCP (ANSI/NFPA 262) and FT6 (CSA C22.2 No. 232)
Crush Resistance 650 N/cm
Impact Resistance 20 impacts
Flex Resistance 25 cycles
These specifications are subject to change without prior notification.

OCC indoor/outdoor tight-buffered fiber optic cables meet functional requirements of the following standards:

  • UL 1651
  • ANSI/NFPA 262

  • ICEA-S-83-596

Instruction Sheets