G-Series Subgrouping Riser Rated Tray Cables

Applications:

  • Ideal for installations requiring a rugged and reliable cable design where maximum mechanical and environmental protection is necessary
  • Typical industrial uses are factory automation, power generation and other utilities, oil and gas refining, and surface mining

Features:

  • Best design for multimode and single-mode fiber hybrid/composite cables
  • Design allows milti-fiber subcables to be routed to multiple locations such as wiring racks and closets
  • Independently tested for CSA C22.2 No. 230 (tray cables)
  • Color-coded subcables are easy to identify for improved cable management in routing and termination
  • Designed for indoor/outdoor installations, including cable trays
  • 12-144-fiber configurations are available with 6-12 fibers per subcable
  • Low-temperature PVC outer jacket (J material) provides excellent performance and flexability at low temperatures
  • Jacket is UV, fungus and water resistant
  • Wide operating temperature range of -50°C to +75°C
  • Core-Locked™ jacket prevents cable from flattening and the jacket from wrinkling in tight bends
    • Permits pulling with direct attachment of wire mesh grip; no need to access inner aramid strength members
    • Improved crush and tear resistance
    • Contains 25% more material than conventional jackets
  • High crush and tensile load ratings compares to similar tray service fiber optic cables
  • Oil resistant for use in industrial applications
  • UL listed in accordance with NEC section 770.179(b) for use in vertical runs in building riser shafts or from floor to floor
  • Designed to exceed the flammability requirements of Chapter 8 IEEE 383
  6 Fiber Subunits 12 Fiber Subunits
Operating Temperature -50°C to +75°C -50°C to +75°C
Storage Temperature -55°C to +85°C -55°C to +85°C
Installation Temperature (cable temp.) -30°C to +60°C -30°C to +60°C
Flame Retardancy UL listed type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232) UL listed type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232)
Crush Resistance 2,100 N/cm 2,100 N/cm
Impact Resistance 1,500 impacts 1,500 impacts
Flex Resistance 2,000 cycles 2,000 cycles
These specifications are subject to change without prior notification.

OCC indoor/outdoor tight-buffered fiber optic cables meet functional requirements of the following standards:

  • UL 1666
  • CSA C22.2 No. 232
  • CSA C22.2 No. 230

  • GR-409-CORE
  • ICEA-S-104-696
  • ICEA-S-83-596
  • TIA-568
  • TIA-598

Instruction Sheets