D-Series Distribution – Aluminum Interlocking Armored – Plenum – Indoor/Outdoor Rated Cables

Installation zone RECOMMENDATION
1
1
1
1
  • Ideal for industrial and other installations requiring a metallic conduit
  • Interlocking pre-loaded armor may eliminate the need for conduit, reducing installation costs

Applications

  • Used in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces
  • Ideal configuration for a single termination point requiring multiple fibers
  • Aluminum interlocking armor with Low-Smoke PVC overjacket
  • Interlocking armor can be easily removed leaving an intact inner cable
  • Greater flexibility than corrugated steel armored (CST) cables
  • Ideal for locations that require conduit for cable protection
  • Indoor/Outdoor plenum cables eliminate the need for costly cable transitions in different installation environments

Features

  • UL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces
  • Low-smoke PVC inner and outer jackets
  • 2 to 24 fibers
  • Cable materials are Indoor/Outdoor UL-Listed OFCP and also UV, water and fungus resistant
  • High performance tight-buffered coating on each fiber for environmental and mechanical protection
  • 900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber.
  • Helically stranded core for flexibility, survival in difficult installations, and mechanical protection for the fibers
  • Can be installed outside and in plenum or riser pathways inside, eliminating the need to transition cable types between environments

Characteristics

CharacteristicPlenum (Indoor/Outdoor)
Operating Temp-40°C to +70°C
Storage Temp-40°C to +70°C
Install Temp0°C to +60°C
Flame RetardancyUL Listed Type OFCP NFPA262 FT6 (CSA C22.2 No. 232)
Crush Resist650 N/cm
Impact Resist20 impacts
Flex Resist25 cycles
Jacket TypeT

Standards

OCC indoor/outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:

  • ANSI/NFPA 262
  • ICEA-S-83-596
  • UL 1651

Specifications

(ILA) – PLENUM- (“T” jacket)

Tensile LoadMinimum Bend Radius
Fiber CountPart NumberSpec SheetDiameter mm
(in)
Weight kg/km
(lbs/1,000ft)
Installation N
(lbs)
Operation N
(lbs)
Installation cm
(in)
Longer Term cm
(in)
 
2DX002T***9*PI8 Download Spec Sheet 12.6
(0.5)
99.0
(149.0)
1,350
(300)
400
(90)
25.2
(9.9)
18.9
(7.4)
4DX004T***9*PI8 Download Spec Sheet 12.6
(0.5)
147.0
(99.0)
1,350
(300)
400
(90)
25.2
(9.9)
18.9
(7.4)
6DX006T***9*PI8 Download Spec Sheet 12.6
(0.5)
147.0
(99.0)
1,350
(300)
400
(90)
25.2
(9.9)
18.9
(7.4)
8DX008T***9*PI8 Download Spec Sheet 12.6
(0.5)
147.0
(99.0)
1,350
(300)
400
(90)
25.2
(9.9)
18.9
(7.4)
12DX012T***9*PI8 Download Spec Sheet 14.1
(0.6)
196.0
(132.0)
1,350
(300)
400
(90)
28.6
(11.3)
21.2
(8.3)
18DX018T***9*PI8 Download Spec Sheet 14.1
(0.6)
196.0
(132.0)
1,350
(300)
400
(90)
28.6
(11.3)
21.2
(8.3)
24DX024T***9*PI8 Download Spec Sheet 15.1
(0.6)
214.0
(144.0)
1,350
(300)
400
(90)
30.2
(11.9)
22.7
(8.9)
img
Talk to a knowledgeable OCC Expert that can find or customize a product to fit your specifications. 800-622-7711